Absolute reliability and validity of the OptoGait(TM) system to measure spatiotemporal gait parameters during running

Primer Autor
Garcia-Pinillos, Felipe
Co-autores
Latorre-Roman, Pedro A.
Chicano-Gutierrez, Jose M.
Ruiz-Malagon, Emilio J.
Parraga-Montilla, Juan A.
Roche-Seruendo, Luis E.
Título
Absolute reliability and validity of the OptoGait(TM) system to measure spatiotemporal gait parameters during running
Editorial
SAGE PUBLICATIONS LTD
Revista
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART P-JOURNAL OF SPORTS ENGINEERING AND TECHNOLOGY
Lenguaje
en
Resumen
The biomechanics of walking and running, in both ground and treadmill conditions, have been extensively analysed and important differences have been reported. Despite some previous studies having examined the validity and reliability of the OptoGait (TM) system for measuring gait characteristics during walking, no previous works have determined the reliability and validity of this system while running on a treadmill. Therefore, this study aimed to determine the absolute reliability (within-subject variation) and evaluate the concurrent validity of the OptoGait (TM) system for measuring spatiotemporal variables while running at a comfortable speed by comparing data with a highly accurate system of measuring those parameters (i.e. video analysis at 1000 Hz). Forty-nine endurance runners performed a running protocol on a treadmill at a comfortable speed. Two systems were used to collect data: OptoGait (TM) system and high-speed video analysis at 1000 Hz. The coefficient of variation (CV) was calculated as a measure of absolute reliability. The OptoGait (TM) system reported a CV range between 2.2% and 11.4% for spatiotemporal parameters, while the video analysis showed a CV range between 0.02% and 9.9%. To determine concurrent validity, intra class correlation coefficients (ICC) and pairwise comparisons of means (t-test) were calculated between data from both systems. Although the paired t-test demonstrated significant differences between systems, a high level of agreement (ICC > 0.89) was obtained in spatiotemporal parameters between systems. When compared to a high-speed video analysis at 1000 Hz, the results indicate that the OptoGait (TM) system is a reliable and valid tool to measure spatiotemporal gait characteristics while running on a treadmill at a comfortable speed.
Tipo de Recurso
artículo original
doi
10.1177/1754337120977409
Formato Recurso
PDF
Palabras Claves
Gait
kinematic
runners
video analysis
PHOTOELECTRIC-CELL SYSTEM
TEST-RETEST RELIABILITY
SPORTS-MEDICINE
VIDEO ANALYSIS
STEP RATE
BIOMECHANICS
PERFORMANCE
KINEMATICS
VARIABLES
ECONOMY
Ubicación del archivo
Categoría OCDE
Ingeniería Mecánica
Ciencias del Deporte
Materias
Marcha
cinemática
corredores
análisis de vídeo
SISTEMA DE CÉLULAS FOTOELÉCTRICAS
TEST-REEST FIABILIDAD
MEDICINA-DEPORTIVA
ANÁLISIS DE VIDEO
RITMO DE PASOS
BIOMECÁNICA
RENDIMIENTO
CINEMÁTICA
VARIABLES
ECONOMÍA
Título de la cita (Recomendado-único)
Absolute reliability and validity of the OptoGait(TM) system to measure spatiotemporal gait parameters during running
Página de inicio (Recomendado-único)
90
Página final (Recomendado-único)
96
Identificador del recurso (Mandatado-único)
artículo original
Versión del recurso (Recomendado-único)
version publicada
Condición de la licencia (Recomendado-repetible)
0
Derechos de acceso
metadata
Access Rights
metadata
Id de Web of Science
WOS:000600184200001
Revisa las metricas alternativas de Almetrics
Revisa las citaciones de Dimensions