Análisis Comparativo de la Visualización del Canal Mandibular Mediante Tomografía Computarizada Cone Beam en Humanos
Primer Autor |
Nahuelcura Millan, Nestor
|
Co-autores |
Matamala Vargas, Fernando
Bastias Nahuelhuan, Claudio
|
Título |
Análisis Comparativo de la Visualización del Canal Mandibular Mediante Tomografía Computarizada Cone Beam en Humanos
|
Editorial |
SOC CHILENA ANATOMIA
|
Revista |
INTERNATIONAL JOURNAL OF MORPHOLOGY
|
Lenguaje |
es
|
Resumen |
"One of the structures of greatest interest in the maxillofacial region is the mandibular canal, where its preservation optimizes the success of clinical procedures. Due to its disposition inside the mandible, in vivo visualization requires the use of radiographic techniques, among which the Cone Beam CT (CBCT) stands out. The objective of this work is to compare the visualization of the human mandibular canal by means of CBCT images with different observers and radiation programs. Using images generated with CBCT in dry mandibles with different acquisition programs, coronal slices were obtained in the anterior, middle and posterior sectors of the mandibular canal, with a total of 240 measurements, which included two voxel sizes and two doses different radiation sources. Each of the images was evaluated by a Dentist, an Anatomy Master's degree and a specialist in Oral & Maxillofacial Radiology. Percentages of visualization according to observer were obtained for each image acquisition program. The Cochran Q test yielded differences between the observers (p<0.05) and the McNemar test defined these dissimilarities between the specialist and the other observers, but not between the latter. The Yates and Mann-Whitney U tests did not show statistical differences according to the acquisition program (p>0.05). The degree of expertise of the observer influences the visualization and its precision. In turn, using an image acquisition program with a different voxel/radiation dose not affect the visualization, since it depends on the anatomy of the structure itself. A protocol with less radiation could be used in patients complying with the ALARA (""As Low As Reasonably Achievable"") premise."
|
Tipo de Recurso |
artículo original
|
doi |
10.4067/S0717-95022022000100129
|
Formato Recurso |
PDF
|
Palabras Claves |
Mandibular canal
Jaw
Cone Beam CT
VISIBILITY
AMERICAN
IMAGES
|
Ubicación del archivo | |
Categoría OCDE |
Anatomía y Morfología
|
Materias |
Canal mandibular
Mandíbula
CT de haz cónico
VISIBILIDAD
AMERICANO
IMÁGENES
|
Título de la cita (Recomendado-único) |
Análisis Comparativo de la Visualización del Canal Mandibular Mediante Tomografía Computarizada Cone Beam en Humanos
|
Página de inicio (Recomendado-único) |
129
|
Página final (Recomendado-único) |
136
|
Identificador del recurso (Mandatado-único) |
artículo original
|
Versión del recurso (Recomendado-único) |
version publicada
|
License |
CC BY-NC 4.0
|
Condición de la licencia (Recomendado-repetible) |
CC BY-NC 4.0
|
Derechos de acceso |
acceso abierto
|
Access Rights |
acceso abierto
|
Id de Web of Science |
WOS:000770886000020
|
- Colecciones
- Colección Publicaciones Científicas