Heart rate monitoring of the endurance runner during high intensity interval training: Influence of device used on training functions

Primer Autor
Ruiz-Alias, Santiago A.
Co-autores
Garcia-Pinillos, Felipe
Soto-Hermoso, Victor M.
Ruiz-Malagon, Emilio J.
Título
Heart rate monitoring of the endurance runner during high intensity interval training: Influence of device used on training functions
Editorial
SAGE PUBLICATIONS LTD
Revista
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART P-JOURNAL OF SPORTS ENGINEERING AND TECHNOLOGY
Lenguaje
en
Resumen
Photoplethysmography (PPG) heart rate devices are greatly affected by the motion artifacts of running. As a result, their application in training load systems and effort control strategies based on heart rate (HR) could be debatable. In 2019, Polar applied some new features on their PPG devices to improve their accuracy. Thus, the purpose of this study was to determine the level of agreement between the new PPG system Polar Precision Prime (TM) and the chest strap Polar H10 (reference system) in the HR monitoring during an interval running protocol. A group of 37 long distance runners completed an interval running protocol of 10 min composed of five 1-min trials with an active break of 1-min between each trial. An excellent reliability (ICC > 0.9) was obtained for the entire interval running protocol with the lowest values in the first 2 min (ICC = 0.960-0.949), slight differences between intensities (ICC = 0.992-0.986), and a reduction of the observed tendency (ICC > 0.9) when the Edwards quantification model was applied (ICC = 0.877-0.967). The Bland-Altman plots with the final HR values of each trial establish a systematic bias (<1 bpm) for all intervals with a random error (<4 bpm), except in the first trial which had a higher random error (6.85 bpm). In conclusion, the innovations applied in the new PPG system provide the accuracy required for use in diverse functions, including endurance running.
Fecha Publicación
2023
Tipo de Recurso
artículo original
Derecho de Acceso
registro bibliográfico
doi
10.1177/17543371211037035
Formato Recurso
PDF
Palabras Claves
Heart rate
running
wearable
sport watch
Polar Precision Prime (TM)
endurance training
Ubicación del archivo
Categoría OCDE
Ingeniería
Ciencias del Deporte
Ciencias del Deporte y Acondicionamiento Físico
Fisiología
Tecnología de la Información y Computación
Materias
Ritmo cardiaco
correr
wearable
reloj deportivo
Polar Precision Prime (TM)
entrenamiento de resistencia
Página de inicio (Recomendado-único)
166.0
Página final (Recomendado-único)
172
Identificador del recurso (Mandatado-único)
artículo original
Versión del recurso (Recomendado-único)
versión publicada
Derechos de acceso
metadata
Access Rights
metadata
Id de Web of Science
WOS:000681430600001
ISSN
1754-3371
Tipo de ruta
verde / hibrido
Categoría WOS
Ingeniería
Ciencias del Deporte
Revisa las metricas alternativas de Almetrics
Revisa las citaciones de Dimensions