Heart rate monitoring of the endurance runner during high intensity interval training: Influence of device used on training functions
Primer Autor |
Ruiz-Alias, Santiago A.
|
Co-autores |
Garcia-Pinillos, Felipe
Soto-Hermoso, Victor M.
Ruiz-Malagon, Emilio J.
|
Título |
Heart rate monitoring of the endurance runner during high intensity interval training: Influence of device used on training functions
|
Editorial |
SAGE PUBLICATIONS LTD
|
Revista |
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART P-JOURNAL OF SPORTS ENGINEERING AND TECHNOLOGY
|
Lenguaje |
en
|
Resumen |
Photoplethysmography (PPG) heart rate devices are greatly affected by the motion artifacts of running. As a result, their application in training load systems and effort control strategies based on heart rate (HR) could be debatable. In 2019, Polar applied some new features on their PPG devices to improve their accuracy. Thus, the purpose of this study was to determine the level of agreement between the new PPG system Polar Precision Prime (TM) and the chest strap Polar H10 (reference system) in the HR monitoring during an interval running protocol. A group of 37 long distance runners completed an interval running protocol of 10 min composed of five 1-min trials with an active break of 1-min between each trial. An excellent reliability (ICC > 0.9) was obtained for the entire interval running protocol with the lowest values in the first 2 min (ICC = 0.960-0.949), slight differences between intensities (ICC = 0.992-0.986), and a reduction of the observed tendency (ICC > 0.9) when the Edwards quantification model was applied (ICC = 0.877-0.967). The Bland-Altman plots with the final HR values of each trial establish a systematic bias (<1 bpm) for all intervals with a random error (<4 bpm), except in the first trial which had a higher random error (6.85 bpm). In conclusion, the innovations applied in the new PPG system provide the accuracy required for use in diverse functions, including endurance running.
|
Fecha Publicación |
2023
|
Tipo de Recurso |
artículo original
|
Derecho de Acceso |
registro bibliográfico
|
doi |
10.1177/17543371211037035
|
Formato Recurso |
PDF
|
Palabras Claves |
Heart rate
running
wearable
sport watch
Polar Precision Prime (TM)
endurance training
|
Ubicación del archivo | |
Categoría OCDE |
Ingeniería
Ciencias del Deporte
Ciencias del Deporte y Acondicionamiento Físico
Fisiología
Tecnología de la Información y Computación
|
Materias |
Ritmo cardiaco
correr
wearable
reloj deportivo
Polar Precision Prime (TM)
entrenamiento de resistencia
|
Página de inicio (Recomendado-único) |
166.0
|
Página final (Recomendado-único) |
172
|
Identificador del recurso (Mandatado-único) |
artículo original
|
Versión del recurso (Recomendado-único) |
versión publicada
|
Derechos de acceso |
metadata
|
Access Rights |
metadata
|
Id de Web of Science |
WOS:000681430600001
|
ISSN |
1754-3371
|
Tipo de ruta |
verde / hibrido
|
Categoría WOS |
Ingeniería
Ciencias del Deporte
|