Using an Attachment System with PEEK Matrices for Single-Implant Overdentures: In Vitro Retention Force

Primer Autor
Borie, Eduardo
Co-autores
Fugariu, Ioana
de Souza, Raphael Freitas
Rosas, Eduardo
Título
Using an Attachment System with PEEK Matrices for Single-Implant Overdentures: In Vitro Retention Force
Editorial
MDPI
Revista
JOURNAL OF CLINICAL MEDICINE
Lenguaje
en
Resumen
Single-implant overdentures (SIOs) represent a major biomechanical challenge in terms of prosthetic retention. The Novaloc attachment system has the potential to overcome those challenges when used for SIOs, due to the use of PEEK matrices. This study compared the retentive force of the Novaloc attachment to the traditional Locator system, before and after cyclic insertion-removal cycles. Three Novaloc matrices (white, yellow, and green, corresponding to low, medium, and high retention, respectively) and Locator (medium retention) were tested, totalling four groups. Retentive force was measured using an Imada force gauge before and after 1095 insertion-removal cycles, corresponding to a year of SIO wearing. Retention was tested with the implants angulated at 0, 10, and 20 degrees. Data for the different groups, angles, and cycling periods were tested via linear regression analysis and two-way ANOVA (alpha = 0.05). Although the Locator system yielded higher retention forces in general, it lost a much higher percentage of retention with cycling. This trend was similar with the three angles, with forces being inversely proportional to the implant angulation. The authors conclude that Novaloc may provide more reliable retention for SIOs due to their higher resistance to insertion-removal cycling.
Fecha Publicación
2023
Tipo de Recurso
artículo original
doi
10.3390/jcm12062159
Formato Recurso
PDF
Palabras Claves
complete denture
denture attachment
implant-supported dental prosthesis
prosthesis failure
Ubicación del archivo
Categoría OCDE
Medicina general e interna
Materias
dentadura completa
accesorio para dentaduras postizas
prótesis dentales implantosoportadas
fracaso de la prótesis
Identificador del recurso (Mandatado-único)
artículo original
Versión del recurso (Recomendado-único)
versión publicada
License
CC BY 4.0
Condición de la licencia (Recomendado-repetible)
CC BY 4.0
Derechos de acceso
acceso abierto
Access Rights
acceso abierto
Id de Web of Science
WOS:000956042900001
Tipo de ruta
verde# dorado
Categoría WOS
Medicina general e interna
Revisa las metricas alternativas de Almetrics
Revisa las citaciones de Dimensions