Level of Agreement between the MotionMetrix System and an Optoelectronic Motion Capture System for Walking and Running Gait Measurements

Primer Autor
Garcia-Pinillos, Felipe
Co-autores
Jaen-Carrillo, Diego
Chicano-Gutierrez, Jose M.
Perez-Castilla, Alejandro
Soto-Hermoso, Victor
Molina-Molina, Alejandro
Ruiz-Alias, Santiago A.
Título
Level of Agreement between the MotionMetrix System and an Optoelectronic Motion Capture System for Walking and Running Gait Measurements
Editorial
MDPI
Revista
SENSORS
Lenguaje
en
Resumen
Markerless motion capture systems (MCS) have been developed as an alternative solution to overcome the limitations of 3D MCS as they provide a more practical and efficient setup process given, among other factors, the lack of sensors attached to the body. However, this might affect the accuracy of the measures recorded. Thus, this study is aimed at evaluating the level of agreement between a markerless MSC (i.e., MotionMetrix) and an optoelectronic MCS (i.e., Qualisys). For such purpose, 24 healthy young adults were assessed for walking (at 5 km/h) and running (at 10 and 15 km/h) in a single session. The parameters obtained from MotionMetrix and Qualisys were tested in terms of level of agreement. When walking at 5 km/h, the MotionMetrix system significantly underestimated the stance and swing phases, as well as the load and pre-swing phases (p < 0.05) reporting also relatively low systematic bias (i.e., = -0.03 s) and standard error of the estimate (SEE) (i.e., =0.02 s). The level of agreement between measurements was perfect (r > 0.9) for step length left and cadence and very large (r > 0.7) for step time left, gait cycle, and stride length. Regarding running at 10 km/h, bias and SEE analysis revealed significant differences for most of the variables except for stride time, rate and length, swing knee flexion for both legs, and thigh flexion left. The level of agreement between measurements was very large (r > 0.7) for stride time and rate, stride length, and vertical displacement. At 15 km/h, bias and SEE revealed significant differences for vertical displacement, landing knee flexion for both legs, stance knee flexion left, thigh flexion, and extension for both legs. The level of agreement between measurements in running at 15 km/h was almost perfect (r > 0.9) when comparing Qualisys and MotionMetrix parameters for stride time and rate, and stride length. The agreement between the two motion capture systems varied for different variables and speeds of locomotion, with some variables demonstrating high agreement while others showed poor agreement. Nonetheless, the findings presented here suggest that the MotionMetrix system is a promising option for sports practitioners and clinicians interested in measuring gait variables, particularly in the contexts examined in the study.
Fecha Publicación
2023
Tipo de Recurso
artículo original
doi
10.3390/s23104576
Formato Recurso
PDF
Palabras Claves
analysis
biomechanics
gait
markerless
motion
reliability
Ubicación del archivo
Categoría OCDE
Química
Ingeniería
Instrumentos e instrumentación
Materias
análisis
biomecánica
paso
sin marcador
movimiento
fiabilidad
Identificador del recurso (Mandatado-único)
artículo original
Versión del recurso (Recomendado-único)
versión publicada
License
CC BY 4.0
Condición de la licencia (Recomendado-repetible)
CC BY 4.0
Derechos de acceso
acceso abierto
Access Rights
acceso abierto
Id de Web of Science
WOS:000998324300001
Tipo de ruta
verde# dorado
Categoría WOS
Química
Ingeniería
Instrumentos e instrumentación
Referencia del Financiador (Mandatado si es aplicable-repetible)
ERDDF PID2020-115600RB-C21
Revisa las metricas alternativas de Almetrics
Revisa las citaciones de Dimensions