Water-equivalence of gel dosimeters for radiology medical imaging
| Primer Autor |
Valente, M.
|
| Co-autores |
Vedelago, J.#Chacon, D.#Mattea, F.#Velasquez, J.#Perez, P.
|
| Título |
Water-equivalence of gel dosimeters for radiology medical imaging
|
| Editorial |
PERGAMON-ELSEVIER SCIENCE LTD
|
| Revista |
APPLIED RADIATION AND ISOTOPES
|
| Lenguaje |
en
|
| Resumen |
International dosimetry protocols are based on determinations of absorbed dose to water. Ideally, the phantom material should be water equivalent, that is, it should have the same absorption and scatter properties as water. This study presents theoretical, experimental and Monte Carlo modeling of water-equivalence of Fricke and polymer (NIPAM, PAGAT and itaconic acid ITABIS) gel dosimeters. Mass and electronic densities along with effective atomic number were calculated by means of theoretical approaches. Samples were scanned by standard computed tomography. Photon mass attenuation coefficients and electron stopping powers were examined. Theoretical, Monte Carlo and experimental results confirmed good water-equivalence for all gel dosimeters. Overall variations with respect to water in the low energy radiology range (up to 130 kVp) were found to be less than 3% in average.
|
| Tipo de Recurso |
artículo original#presentación de congreso
|
| Description |
This study was partially financed by CONICET (Argentina) project ESPORA I - PIP 112-20130100658CO, SeCyT-UNC (Argentina) project DOSCOM I and DI-UFRO (Chile) projects DI-16-6008 and DI-17-1003. Authors are grateful to ICOS radiology technicians, especially Camila Vidal Bravo.
Este estudio fue financiado parcialmente por el proyecto ESPORA I - PIP 112-20130100658CO del CONICET (Argentina), el proyecto DOSCOM I de la SeCyT-UNC (Argentina) y los proyectos DI-16-6008 y DI-17-1003 de la DI-UFRO (Chile). Los autores agradecen a los técnicos de radiología de ICOS, especialmente a Camila Vidal Bravo.
|
| doi |
10.1016/j.apradiso.2018.03.005
|
| Formato Recurso |
pdf
|
| Palabras Claves |
Gel dosimetry# Water-equivalence# Computed tomography
|
| Ubicación del archivo |
http://dx.doi.org/10.1016/j.apradiso.2018.03.005
|
| Categoría OCDE |
Chemistry, Inorganic & Nuclear# Nuclear Science & Technology# Radiology, Nuclear Medicine & Medical Imaging
|
| Materias |
Dosimetría en gel# Equivalencia de agua# tomografía computarizada
|
| Disciplinas de la OCDE |
Radiología, Medicina Nuclear y de Imágenes
Otras Especialidades de la Física
Físico-Química
|
| Id de Web of Science |
WOS:000449448300031
|
| Título de la cita (Recomendado-único) |
Water-equivalence of gel dosimeters for radiology medical imaging
|
| Identificador relacionado |
http://hdl.handle.net/11336/91615
|
| Identificador del recurso (Mandatado-único) |
artículo original#presentación de congreso
|
| Versión del recurso (Recomendado-único) |
version publicada
|
| Editorial |
PERGAMON-ELSEVIER SCIENCE LTD
|
| Revista/Libro |
APPLIED RADIATION AND ISOTOPES
|
| Categoría WOS |
Química, Inorgánica y Nuclear# Ciencia y tecnología nucleares# Radiología, Medicina Nuclear e Imágenes Médicas
|
| ISSN |
0969-8043
|
| Idioma |
en
|
| Referencia del Financiador (Mandatado si es aplicable-repetible) |
CONICET ESPORA I - PIP 112-20130100658CO#UFRO DI-16-6008#UFRO DI-17-1003#ICOS
CONICET (Argentina) ESPORA I - PIP 112-20130100658CO]
SeCyT-UNC (Argentina) DOSCOM I
UFRO DI-16-6008
UFRO DI-17-1003
|
| Descripción |
This study was partially financed by CONICET (Argentina) project ESPORA I - PIP 112-20130100658CO, SeCyT-UNC (Argentina) project DOSCOM I and DI-UFRO (Chile) projects DI-16-6008 and DI-17-1003. Authors are grateful to ICOS radiology technicians, especially Camila Vidal Bravo.
|
| Formato |
pdf
|
| Tipo de ruta |
hibrida#verde
|
| Access Rights |
metadata
|
| Derechos de acceso |
metadata
|
| Página de inicio (Recomendado-único) |
34
|
| Página final (Recomendado-único) |
50
|