Integration of Fricke gel dosimetry with Ag nanoparticles for experimental dose enhancement determination in theranostics

Primer Autor
Valente, M.
Co-autores
Vedelago, J.#Mattea, F.
Título
Integration of Fricke gel dosimetry with Ag nanoparticles for experimental dose enhancement determination in theranostics
Editorial
PERGAMON-ELSEVIER SCIENCE LTD
Revista
APPLIED RADIATION AND ISOTOPES
Lenguaje
en
Resumen
The use and implementation of nanoparticles in medicine has grown exponentially in the last twenty years. Their main applications include drug delivery, theranostics, tissue engineering and magneto function. Dosimetry techniques can take advantage of inorganic nanoparticles properties and their combination with gel dosimetry techniques could be used as a first step for their later inclusion in radio-diagnostics or radiotherapy treatments. The present study presents preliminary results of properly synthesized and purified silver nanoparticles integration with Fricke gel dosimeters. Used nanoparticles presented mean sizes ranging from 2 to 20 nm, with a lognormal distribution. Xylenol orange concentration in Fricke gel dosimeter was adjust in order to allow sample's optical readout, accounting nanoparticles plasmon. Dose enhancement was assessed irradiating dosimeters setting X-ray beams energies below and above silver K-edge. Monte Carlo simulations were used to estimate the dose enhancement in the experiments and compare with the trend obtained in the experimental results.
Tipo de Recurso
artículo original#presentación de congreso
Description
This study was partially financed by CONICET (Argentina) project ESPORA I - PIP 112-20130100658CO, SeCyT-UNC (Argentina) project DOSCOM I and 30720150101410CB, and DI-UFRO (Chile) projects DI-16-6008 and DI-17-1003.
Este estudio fue financiado parcialmente por el proyecto ESPORA I - PIP 112-20130100658CO del CONICET (Argentina), el proyecto DOSCOM I y 30720150101410CB de la SeCyT-UNC (Argentina), y los proyectos DI-16-6008 y DI-17-1003 de la DI-UFRO (Chile).
doi
10.1016/j.apradiso.2018.02.028
Formato Recurso
pdf
Palabras Claves
Fricke gel dosimetry# Ag nanoparticles# Dose enhancement
Ubicación del archivo
http://dx.doi.org/10.1016/j.apradiso.2018.02.028
Categoría OCDE
Chemistry, Inorganic & Nuclear# Nuclear Science & Technology# Radiology, Nuclear Medicine & Medical Imaging
Materias
dosimetría en gel de Fricke# Nanopartículas de Ag# Mejora de la dosis
Disciplinas de la OCDE
Ingeniería Médica
Nanomateriales (Producción y Propiedades)
Física Nuclear
Id de Web of Science
WOS:000449448300029
Título de la cita (Recomendado-único)
Integration of Fricke gel dosimetry with Ag nanoparticles for experimental dose enhancement determination in theranostics
Identificador relacionado
hdl.handle.net/11336/90508
Identificador del recurso (Mandatado-único)
artículo original#presentación de congreso
Versión del recurso (Recomendado-único)
version publicada
Editorial
PERGAMON-ELSEVIER SCIENCE LTD
Revista/Libro
APPLIED RADIATION AND ISOTOPES
Categoría WOS
Química, Inorgánica y Nuclear# Ciencia y tecnología nucleares# Radiología, Medicina Nuclear e Imágenes Médicas
ISSN
0969-8043
Idioma
en
Referencia del Financiador (Mandatado si es aplicable-repetible)
CONICET ESPORA I - PIP 112-20130100658CO#SeCyT-UNC DOSCOM I 30720150101410CB#UFRO DI-16-6008#UFRO DI-17-1003
CONICET (Argentina) ESPORA I - PIP 112-20130100658CO
SeCyT-UNC (Argentina) DOSCOM I 30720150101410CB
UFRO DI-16-6008
UFRO DI-17-1003
30720150101410CB]
Descripción
This study was partially financed by CONICET (Argentina) project ESPORA I - PIP 112-20130100658CO, SeCyT-UNC (Argentina) project DOSCOM I and 30720150101410CB, and DI-UFRO (Chile) projects DI-16-6008 and DI-17-1003.
Formato
pdf
Tipo de ruta
hibrida#verde
Access Rights
metadata
Derechos de acceso
metadata
Página de inicio (Recomendado-único)
232
Página final (Recomendado-único)
238
Revisa las metricas alternativas de Almetrics
Revisa las citaciones de Dimensions