Mechanical stability of 2-plate versus 4-plate osteosynthesis in advancement Le Fort I osteotomy. An in vitro study
| Primer Autor |
Olate, S.
|
| Co-autores |
Pozzer, L.#Cavalieri-Pereira, L.#Navarro, P.#de Albergaria Barbosa, J. R.
|
| Título |
Mechanical stability of 2-plate versus 4-plate osteosynthesis in advancement Le Fort I osteotomy. An in vitro study
|
| Editorial |
ELSEVIER SCIENCE BV
|
| Revista |
JOURNAL OF STOMATOLOGY ORAL AND MAXILLOFACIAL SURGERY
|
| Lenguaje |
en
|
| Resumen |
Introduction: Stability in orthognathic surgery is nowadays considered as efficient and adequate. The objective of this study was to determine and to compare the mechanical resistance to vertical load of a Le Fort I advancement osteotomy stabilized by mean of two different osteosynthesis techniques, one using two 10-hole pre-bent T-shaped plates, the other using four manually bent 4-hole L-and J-shaped plates. Materiel and methods: Standardized Le Fort I advancement osteotomies have been made on polyurethane models. The maxillary advancement was 5 mm. Two groups of five models each were created. Group 1 was stabilized by mean of two 10-hole pre-bent T-shaped plates fixed by monocortical screws in the paranasal region. Group 2 was stabilized by mean of manually bent four 4-hole L-shaped plates fixed monocortical screws in the zygomatic and paranasal regions. A testing machine was used to load vertically the models at the range of 1 mm/min linear displacement until peak load and system failure. Statistical analysis was realized using ANOVA and t-test, considering P as significant if < 0.005. Results: The maximal tolerated load was 15 N in group 1and 42.71 N in group 2 ( P = 0.003). Discussion: The use of two T-shaped 10-holes pre-bent plates allows for less resistance in vertical loading than the use of four 4-holes manually bent L-shaped plates. (C) 2016 Elsevier Masson SAS. All rights reserved.
|
| Tipo de Recurso |
Artículo original
|
| doi |
10.1016/j.jormas.2016.03.001
|
| Formato Recurso |
pdf
|
| Palabras Claves |
Internal fixation# Pre-bend plate# Le Fort I
|
| Ubicación del archivo |
http://dx.doi.org/10.1016/j.jormas.2016.03.001
|
| Categoría OCDE |
Dentistry, Oral Surgery & Medicine
|
| Materias |
Fijación interna# Placa predoblada# El Fuerte I
|
| Disciplinas de la OCDE |
Odontología, Cirugía y Medicina Oral
Cirugía
Ingeniería Médica
|
| Id de Web of Science |
WOS:000424987800002
|
| Título de la cita (Recomendado-único) |
Mechanical stability of 2-plate versus 4-plate osteosynthesis in advancement Le Fort I osteotomy. An <i>in vitro</i> study
|
| Identificador del recurso (Mandatado-único) |
Artículo original
|
| Versión del recurso (Recomendado-único) |
version publicada
|
| Editorial |
ELSEVIER SCIENCE BV
|
| Revista/Libro |
JOURNAL OF STOMATOLOGY ORAL AND MAXILLOFACIAL SURGERY
|
| Categoría WOS |
Odontología, Cirugía Bucal y Medicina
|
| ISSN |
2468-7855
|
| Idioma |
en
|
| Formato |
pdf
|
| Tipo de ruta |
hibrida#verde
|
| Access Rights |
metadata
|
| Derechos de acceso |
metadata
|
| Página de inicio (Recomendado-único) |
798
|
| Página final (Recomendado-único) |
808
|
- Colecciones
- Colección Publicaciones Científicas